Normal power distribution is a critical aspect of efficient and reliable electrical systems, ensuring a consistent electricity supply to various devices and equipment. In the realm of power distribution solutions, Netrack offers a diverse range of products designed to meet the demands of different environments and applications.
One of Netrack's notable products in the normal power distribution category is the "Indian Round Pin" socket. This particular design is tailored to accommodate the Indian standard for electrical connections, providing a secure and compatible interface for various devices. The "Indian Sockets Single Phase" further extends the range, catering to single-phase power requirements with precision and reliability.
For more versatile applications, Netrack offers the "MultiPin" socket, designed to handle multiple connections simultaneously. This feature is particularly beneficial in scenarios where diverse equipment needs to be powered from a single source, streamlining the normal power distribution process.
Netrack's commitment to international standards is evident in products like the "IEC Single Phase Model" and "IEC Sockets Single," which adhere to the International Electrotechnical Commission's specifications. These products ensure seamless compatibility with a global array of devices, contributing to a standardized and efficient
normal power distribution
infrastructure.In environments where higher power demands are prevalent, Netrack provides solutions such as the "Three Phase" socket and the "IEC Three Phase Model." These products are specifically engineered to handle the increased load associated with three-phase power systems, ensuring robust and reliable normal power distribution across industrial and commercial settings.
Netrack's lineup of normal power distribution products encompasses a wide spectrum, from region-specific solutions like the "Indian Round Pin" and "Indian Sockets Single Phase" to globally compatible options such as the "IEC Single Phase Model," "IEC Sockets Single," "Three Phase," and "IEC Three Phase Model." This comprehensive range reflects Netrack's commitment to delivering reliable, standardized, and efficient power distribution solutions for diverse applications.
Indian Round Pin | ||
---|---|---|
1 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 5A, 50/60Hz, Zero U standard with 3 X Indian Round Pin, 5A, Inlet Plug type 6A Indian Round Pin, 5A Fuse - PDU Rating 1.2KVA/ Side feed- 1 mt/ Black | PDU-H-1-IND-A3-X1-Y1-Z0 |
2 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 5A, 50/60Hz, 1 U standard with 4 X Indian Round Pin, 5A, Inlet Plug type 6A Indian Round Pin, 5A Fuse - PDU Rating 1.2KVA/Side Feed-1Mt/Black | PDU-H-1-IND-A4-X1-Y1-Z0 |
3 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 8A, 50/60Hz, 2U standard with 6 X Indian Round Pin 5A, Inlet Plug type 6A Indian Round Pin, 8A Fuse - PDU Rating 1.8KVA/Side feed-1.5Mt/ Black | PDU-H-1-IND-A6-X2-Y1-Z0 |
4 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, 2U standard with 6 X Indian Round Pin 5/15A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA/Side feed-1.5Mt/ Black | PDU-H-1-IND-B6-X3-Y1-Z0 |
5 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, 2U standard with 6 X Indian Round Pin/ Octogonal, 5/15A, Inlet Plug type 16A Indian Round Pin 16A MCB - PDU Rating 3.6KVA/Rear feed-1.5Mt/ Black | PDU-H-1-IND-C6-X3-Y1-Z0 |
Indian Sockets Single Phase | |||
---|---|---|---|
1 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, ,Zero U standard with 10 X Indian Round Pin 5A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA/Bottom feed -3Mt/ Black | PDU-V-1-IND-A10-X3-Y4-Z0 | |
2 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, Zero U standard with 15 X Indian Round Pin 5A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA/Bottom feed -3Mt/ Black | PDU-V-1-IND-A15-X3-Y4-Z0 | |
3 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 32A, 50/60Hz, Zero U standard with 12 X Indian Round Pin 5/15A, 16A MCB X 2 Circuits- PDU Rating 7.3KVA/Bottom feed-3Mt/ Black/ Inlet Plug Not Installed | PDU-V-1-IND-B12-X4-Y4-Z0 | |
4 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 32A, 50/60Hz, Zero U standard with 12 X Indian Round Pin/ Octogonal 5/15A, 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black/ Inlet Plug Not Installed | PDU-V-1-IND-C12-X4-Y4-Z0 |
MultiPin | |||||
---|---|---|---|---|---|
1 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 8A, 50/60Hz, 2U standard with 6 X Intel Multi Pin 5A, Inlet Plug type 6A Indian Round Pin, 8A Fuse - PDU Rating 1.8KVA/Side feed-1.5Mt/ Black | PDU-H-1-MP-D6-X2-Y1-Z0 | |||
2 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, 2U standard with 6 X Intel Multi Pin 6/13A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA/Side feed-1.5Mt/ Black | PDU-H-1-MP-E6- X3-Y1-Z0 | |||
3 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, Zero U standard with 10 X Intel Multipin 5A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA/Bottom feed-3Mt/ Black | PDU-V-1-MP-D10-X3-Y4-Z0 | |||
4 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, Zero U standard with 15 X Intel Multipin 5A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA/Bottom feed-3Mt/ Black | PDU-V-1-MP-D15-X3-Y4-Z0 | |||
5 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 32A, 50/60Hz, Zero U standard with 10 X Intel Multipin 13A, 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black/ Inlet Plug Not Installed | PDU-V-1-MP-E10-X4-Y4-Z0 | |||
6 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 32A, 50/60Hz, Zero U standard with 15 X Intel Multipin 13A, 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black/ Inlet Plug Not Installed | PDU-V-1-MP-E15-X4-Y4-Z0 |
IEC Single Phase Model | |||
---|---|---|---|
1 | 1Ph, 230V, 32A, 1U standard rack mount power distribution unit with 12 X C13, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Rear feed-3Mt/ Black | PDU-H-1-IEC-F12-X4-Y2-Z0 | |
2 | 1Ph, 230V, 32A, 1U standard rack mount power distribution unit with 8 X C19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E),16A MCB X 2 Circuits - PDU Rating 7.3KVA/Rear feed-3Mt/ Black | PDU-H-1-IEC-G8-X4-Y2-Z0 | |
3 | 1Ph, 230V, 32A, 1U standard rack mount power distribution unit with 4 X C13 & 4 XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Rear feed-3Mt/ Black | PDU-H-1-IEC-F4-G4-X4-Y2-Z0 | |
4 | 1Ph, 230V, 32A, 2U standard rack mount power distribution unit with 20 X C13 & 4 XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - - PDU Rating 7.3KVA/Rear feed-3Mt/ Black | PDU-H-1-IEC-F20-G4-X4-Y2-Z0 |
IEC Sockets Single & Three Phase | |||
---|---|---|---|
1 | 1Ph, 230V, 32A, Zero U standard rack mount power distribution unit with 12 X C13, Inlet Plug (Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black | PDU-V-1-IEC-F12-X4-Y4-Z0 | |
2 | 1Ph, 230V, 32A, Zero U standard rack mount power distribution unit with 12 X C19, Inlet Plug (Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black | PDU-V-1-IEC-G12-X4-Y4-Z0 | |
3 | 1Ph, 230V, 32A, Zero U standard rack mount power distribution unit with 12X C13 & 4 X C19, Inlet Plug (Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black | PDU-V-1-IEC-F12-G4-X4-Y4-Z0 | |
4 | 1Ph, 230V, 32A, Zero U standard rack mount power distribution unit with 20 X C13 & 4 X C 19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black | PDU-V-1-IEC-F20-G4-X4-Y4-Z0 |
IEC Three Phase Model | |||
---|---|---|---|
1 | 3Ph, 400V, 16A/Ph, Zero U standard rack mount power distribution unit with 24 X C13, Inlet Plug IEC30916A 4P +E, 16A MCB X 3 Circuits - PDU Rating 11KVA/Bottom feed-3Mt/ Black | PDU-V-3-IEC-F24-X6-Y4-Z0 | |
2 | 3Ph, 400V, 16A/Ph, Zero U standard rack mount power distribution unit with 12 X C13 & 12 XC19, Inlet Plug IEC30916A 4P +E, 16A MCB X 3 Circuits - PDU Rating 11KVA/Bottom feed-3Mt/ Black | PDU-V-3-IEC-F12-G12-X6-Y4-Z0 | |
3 | 3Ph, 400V, 32A/Ph, Zero U standard rack mount power distribution unit with 18 X C13 & 18 XIEC 19, Inlet Plug IEC30916A 4P +E, 16A MCB X 6 Circuits -PDU Rating 22KVA/Bottom feed-3Mt/ Black | PDU-V-3-IEC-F18-G18-X7-Y4-Z0 | |
4 | 3Ph, 400V, 32A/Ph, Zero U standard rack mount power distribution unit with 30 X C13 & 6 XIEC 19, Inlet Plug IEC30932A 4P +E, 16A MCB X 6 Circuits - PDU Rating 22KVA/Bottom feed-3Mt/ Black | PDU-V-3-IEC-F30-G6-X7-Y4-Z0 |