NRSs (sesmic) Series - Ultra rigid multi compartment racks for high density application in data centers & server rooms specially designed for seismic zone. The seismic rack manufactured out of steel sheet, punched, formed, welded and Powder coated with highest quality standards under stringent ISO 9001 | ISO 14001 | ISO 27001 | ISO 45001 Manufacturing & Quality management system to ensure highest quality product.
Standard for racks configuration will be welded to ultra-rigid frame with 4 no pillars of 14 Gauge steel sheet 5 folded profile welded to top and bottom ribbed/ reinforced frame additionally supported depth wise by welding 6 no depth rail 4 folded 75mm 14 Gauge profile & diagonally reinforced by 4 no of 4 folded 50mm 14 gauge profile. Associated with vented top cover with fan mounting provision Front Glass or perforated Metal Door with Lock & Key and Back Vented / Perforated Metal Door with Lock & key and partially vented or Plain side panels 1200 deep rack will be configured with dual side panel. Braced to floor/ raised floor with bracing bolts and additionally braced on top by runway to rigid wall OR Pillar.
Available in 42RU ~ 47RU Variants with 650, 800, 1000 & 1200 Depth configurations 600 & 800 Width configurations.
Technical Data: | |
---|---|
Basic Frame | Steel Folded |
Construction | Welded |
Top & Bottom Cover | Welded to Frame with Cable entry exit cut outs |
Front Door | Lockable Perforated steel Door Plain /Vented |
Rear Door | Lockable Perforated steel Door Plain /Vented |
19” Mounting Angle | Formed Steel |
Standard Finish | Powder coated |
Standard Colour | Grey & Off White OR Black |
Standard Mounting | Braced to Floor/ Raised Floor Bracing Bolts |
Rack Standard | Conforms to DIN 41494 or equivalent standard |
Static Load | 1500 Kg |
Seismic Load | 750 Kg |
Model Matrix & Dimensions | |||||||
---|---|---|---|---|---|---|---|
NRSs Series | H | h | W | w | D | d | Plinth |
42U 600X650 | 2010 | 42U | 600 | 19” | 650 | 550 | |
42U 600X800 | 2010 | 42U | 600 | 19” | 800 | 700 | |
42U 600X1000 | 2010 | 42U | 600 | 19” | 1000 | 900 | |
42U 600X1200 | 2010 | 42U | 600 | 19” | 1200 | 1100 | |
44U 600X650 | 2099 | 44U | 600 | 19” | 650 | 550 | |
44U 600X800 | 2099 | 44U | 600 | 19” | 800 | 700 | |
44U 600X1000 | 2099 | 44U | 600 | 19” | 1000 | 900 | |
44U 600X1200 | 2099 | 44U | 600 | 19” | 1200 | 1100 | |
45U 600X650 | 2143 | 45U | 600 | 19” | 650 | 550 | |
45U 600X800 | 2143 | 45U | 600 | 19” | 800 | 700 | |
45U 600X1000 | 2143 | 45U | 600 | 19” | 1000 | 900 | |
45U 600X1200 | 2143 | 45U | 600 | 19” | 1200 | 1100 | |
47U 600X650 | 2232 | 47U | 600 | 19” | 650 | 550 | Integrated to Frame |
47U 600X800 | 2232 | 47U | 600 | 19” | 800 | 700 | |
47U 600X1000 | 2232 | 47U | 600 | 19” | 1000 | 900 | |
47U 600X1200 | 2232 | 47U | 600 | 19” | 1200 | 1100 | |
42U 800X800 | 2010 | 42U | 800 | 19”/27” | 800 | 700 | |
42U 800X1000 | 2010 | 42U | 800 | 19”/27” | 1000 | 900 | |
42U 800X1200 | 2010 | 42U | 800 | 19”/27” | 1200 | 1100 | |
44U 800X800 | 2099 | 42U | 800 | 19”/27” | 800 | 700 | |
44U 800X1000 | 2099 | 42U | 800 | 19”/27” | 1000 | 900 | |
44U 800X1200 | 2099 | 42U | 800 | 19”/27” | 1200 | 1100 | |
45U 800X800 | 2248 | 45U | 800 | 19”/27” | 800 | 700 | |
45U 800X1000 | 2248 | 45U | 800 | 19”/27” | 1000 | 900 | |
45U 800X1200 | 2248 | 45U | 800 | 19”/27” | 1200 | 1100 | |
47U 800X800 | 2337 | 47U | 800 | 19”/27” | 800 | 700 | |
47U 800X1000 | 2337 | 47U | 800 | 19”/27” | 1000 | 900 | |
47U 800X1200 | 2337 | 47U | 800 | 19”/27” | 1200 | 1100 |
Seismic Rack standards are often specified in terms of the earthquake risk zones. Zones vary from 0 to 4, 0 Zone designating no substantial risk, zones 3 and 4 are generally the regions where Seismic Racks are Required
Manufacturing the Rack & Enclosures understanding above Seismic Zone requirements and designing through FEA ( Finite Element analysis. According to Telcordia (formerly Bellcore) GR-63-CORE Network Equipment Building System (NEBS) requirements for physical protection.