Industrial Products

The safety and effectiveness of a data center largely depend upon the enhanced cooling system for data center. Excessive hot air circulation within a data center can cause equipment to overheat and malfunction. Hence the objective is always to minimize airflow volume by containing each rack within its system to ensure that the hot exhaust air remains isolated from the cold air. Data center cooling with airflow management It requires a lot of planning and effort to manage data center cooling. First, however, the role of airflow management must be considered. It isolates hot and cold airstreams by aligning the racks in parallel rows with the inlet sides of the servers while facing each other across an aisle. This prevents the mixing of the thermal environment within the data center and minimizes the chance of short circuits or outages. A well-planned airflow management is essential because it ensures that the facility maintains a proper temperature throughout

All you need to know about power cords An accidental pullover or any unplanned power outage adversely affects critical business operations. Such downtime negatively impacts a company's credibility, interrupts the organizational workflow, and causes substantial financial loss. Now, primarily accidental pullovers happen due to loose connections in the plug and socket section. However, manhandling of cords is also another reason for such a mishap. This is critical since it can lead to accidents apart from equipment downtime. Hence, securing the cord and socket area with a good-quality product is essential. Business loss due to downtime Despite strategic contingency plans, power shutdowns not only hinder the functioning of an enterprise for a specific timeframe but also hampers the regular and seamless operation of any industrial setup. According to secondary research, an average downtime can cost an organization loss of approximately $5,600 per minute. This is a challenge faced by almost all industry verticals. However, since this results in the expensive and unplanned

5 Great reasons to use Good quality PDUs for your Data Center “Quality is never an accident. It is always the result of intelligent effort." - John Ruskin The quality of a product determines future sustainability and success. A good quality power distribution unit (PDU) is the key to ensuring a reliable power supply since it is the heart of rack solutions. This is important because a low-quality PDU adversely affects the safety of critical equipment. Hence it is essential to choose a PDU with good quality that will support the power consumption of the equipment hosted inside the rack. This will prevent accidental tripping and reduce the chance of equipment downtime. A Certified PDU must also be equipped with a Surge Suppressor to minimize the effect of voltage fluctuation. Such PDU increases dependability in the long run. Quality and suitability of PDUs Now, along with determining the quality of a PDU, it is essential to

Wall mount cabinets are network cabinets that host equipment such as; network switches, patch panels, CCTV cameras, Wi-Fi routers, or other applications and ensure that they stay organized and safe. It is a cost-efficient solution and offers a secure enclosure with protection from tampering, dust, and other hazards. These wall-mount cabinets are 4U, 6U, 9U, 12U, or 15U, and well suited to bring in the Last mile network connectivity or home-based offices with limited workspace. The advantage lies in the fact that it can be installed on the walls, which saves floor space. In addition, since these wall-mount cabinets support remote network distribution, they are often preconfigured cabinets preloaded with connectivity, cable management, PDUs, and related accessories. Features that make them unique The following features of wall mount cabinets make them an intelligent choice for small-scale infrastructure. Easy accessibility: The right or left-hinged back plate design allows rear entry to efficiently access the wires and equipment.Efficient cable management:

Exploring the basics of data center aisle containment: doors, panels, curtains, and more Data centers are vulnerable to damage of any mission-critical equipment or server downtime due to inefficient Air Flow management. It impacts the business's credibility and causes a financial burden for the organization.  Data center challenges  Data centers consist of servers, PDUs, and other various mission-critical equipment that operate 24/7 to support the organizational workflow. Hence these servers and equipment generate immense heat causing electrical short circuits and the data center temperature to rise. Additionally, poor ventilation or inefficient airflow management reduces the data center's cooling capacity, resulting in fire outbreaks. Therefore, considering all the above, creating a long-term solution to monitor and control the temperature within the data center ecosystem is essential. Aisle containment: A cooling solution! Data center aisle containment is critical in ensuring sufficient cooling of the data center. It improves overall airflow management by preventing hot and cold air mixing. This is possible through the efficiency

The Importance of Blanking Panels in Data Centers The need for data center solutions also increased over time with the growing importance of data centers and their critical role in organizations. The focus of such data center solutions is to ensure sufficient cooling of the mission-critical equipment hosted by the data centers, effective airflow management, and efficient data center functioning with zero downtime. Need to keep data centers cool One of the primary determining factors of an organization’s growth is scalability. So, with time organizations need to accommodate additional server racks, which may result in overheating. Here blanking panels play an essential role in the data center solution to keep the air cool.  These blanking panels, also known as filler panels, are deployed on single or multiple unused rack units. They act as a barrier for the unused U Space in racks preventing hot and cold air from mixing. Such an arrangement efficiently prevents

A data center hosting critical IT equipment requires an efficient air flow management strategy to ensure the overall efficiency and sustainability of the data center. Hence, a significant part of the data center’s power is consumed to assure that the servers and equipment are cooled with advanced cooling technologies and optimal cooling solutions. This guarantees equipment protection and empowers the data center to meet the uptime goals in a cost-efficient manner. Need for temperature regulation Maintaining the right temperature and Humidity is quite a struggle for data center designers and managers. However, it is critical to ensure a maintained temperature/Humidity to ensure Equipments are working at Optimal condition. The airflow and temperature regulation problems occur due to varying density requirements of each cabinet in the data center. Issues in maintaining the temperature also occur due to improper cabling and patching work. As it is understood that with every watt of power consumed, it transforms into heat. Facts

The criticality of the role of the data center enhances the need for data center solutions that can ensure sufficient cooling, effective airflow management, and agile functionality of the data center hosting critical equipment and servers. Need for containment solution Containment solution comes as a robust data center solution that is used to separate cold air supply from the hot exhaust air released from the equipment to stabilize the data center's temperature while improving the equipment's efficiency and performance. The containment solution also reduces energy consumption, improving the data center's agility. Now, while offering a containment solution, data centers opt for hot and cold aisle containment to reduce operational costs while increasing cooling efficiency. According to secondary research, about 80% of data centers have already implemented either hot or cold aisle containment. It is the most effective and comprehensive solution to ensure efficient airflow. The Cold Aisle Containment (CAC) solution ensures a uniform flow of cold

In the IT industry, equipment and infrastructure associated with delivering services are critical assets. Hence safeguarding and revamping it from time to time plays an essential role in the overall growth and profitability of the organization. The need for efficient design Datacenter design is one of the key aspects of strategizing and modernizing legacy IT hardware that can considerably enhance the performance and utilization of any data center. For any data center to work successfully and efficiently, it must be designed with sufficient cooling options, consistent power distribution, and a stable network. The following are the aspects that can help a data center design team effectively cater to the business requirements. Ensure reliability of the data centerIncrease availability and, in a way, reduce downtimeEnhance serviceabilitySufficient capacitySupport scalability or future growth plansCost-efficient maintenance Essential factors and considerations Designing of data center takes time, effort, and expense. A data center can efficiently host servers and IT equipment. Choosing a layout or design of a data center

How are data centers cooled? A 21st-century approach The aspect of data center cooling has become crucial with the growing dependency of IT enterprises on the data center. As the older data centers are starting to get replaced by the new hyper-scale facilities, it is becoming even more essential to ensure effective power utilization and efficiency of these new data centers. Need to improve cooling efficiency According to secondary research, data centers consume approximately (1-1.5) % of global electricity, which is expected to rise further with digital transformation. With such an increase in power density, the data centers would need an efficient cooling strategy to keep the equipment from getting damaged due to fire or excessive heat. The cooling system in a modern data center follows the below parameters to achieve efficiency since the cooling system is directly connected with the overall efficiency of the data center. Temperatures of the server